    EXPERIMENTAL PERFORMANCE ASSESSMENT OF AN INTERNALLYCOOLED MINI-CHANNEL FINNED-TUBE HEAT EXCHANGER AS A LIQUID DESICCANT–AIR CONTACTING DEVICE IN A HYBRID AIR-CONDITIONING SYSTEM

    Shemal Parmar1, Jagdish Talpada2, Chetan Somani3, Manish Prajapati4

    Author

    ID: 2911

    DOI: Https://doi.org/10.64771/ijesat.2026.v26.i5.2911

    Abstract :

    Compact Heat Exchangers Employing Minichannel Flow Passages, With Hydraulic Diameters In The Range Of 0.2–3 Mm, Provide Elevated Surface-area-to-volume Ratios, Enhanced Heat-transfer Coefficients And Reduced Refrigerant Inventories Compared With Conventional Finned-tube Coils. The Present Work Investigates The Suitability Of A Finned-tube Mini-channel Coil As The Internally-cooled Air–liquiddesiccant (LD) Contacting Device Of A Hybrid Liquid Desiccant Air-conditioning (LDAC) Unit. An Instrumented Experimental Facility Integrating A Vapour-compression Chiller, A Centrifugal-pump-driven LD Spraying Loop And An Acrylicenclosed Coil Was Constructed And Tested Under Two Modes— Chilled-water-only And Chilled-water With Sprayed Aqueous LD—at Coil-inlet Chilled-water Temperatures Of 17 °C And 22 °C. The Water, Air And Desiccant Mass Flow Rates Were Maintained At 200 L/h, 0.155 Kg/s And 86.71 Kg/h, Respectively. A Peak Total Cooling Rate Of 2.5 KW Was Obtained With Chilled Water Alone At 17 °C, Whereas The Introduction Of The LD Spray Raised Sensible Cooling Marginally (from 1.4 To 1.6 KW At 17 °C) But Reduced Latent Cooling From 1.1 KW To 0.3 KW And Total Cooling From 2.5 KW To 1.9 KW. The Performance Penalty Is Attributed To The Additional Air-side Thermal Resistance Imposed By The Desiccant Film And To The Short Gas–liquid Contact Time At The Prevailing Face Velocity. The Results Delineate The Operating Regime In Which Mini-channel Coils Can Function Effectively As Internally-cooled LD Contactors And Identify The LD-to-air Mass-flow Ratio And Desiccant Pre-cooling As The Dominant Levers For Further Improvement.

    Published:

    02-5-2026

    Issue:

    Vol. 26 No. 5 (2026)


    Page Nos:

    74-79


    Section:

    Articles

    License:

    This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

    How to Cite

    Shemal Parmar1, Jagdish Talpada2, Chetan Somani3, Manish Prajapati4, EXPERIMENTAL PERFORMANCE ASSESSMENT OF AN INTERNALLYCOOLED MINI-CHANNEL FINNED-TUBE HEAT EXCHANGER AS A LIQUID DESICCANT–AIR CONTACTING DEVICE IN A HYBRID AIR-CONDITIONING SYSTEM , 2026, International Journal of Engineering Sciences and Advanced Technology, 26(5), Page 74-79, ISSN No: 2250-3676.

    DOI: https://doi.org/10.64771/ijesat.2026.v26.i5.2911